Anqa Degreaser consumption takes place in the following ways:
By reaction of the oil and the chemical
By drag out of the articles
Consumption of the product is 0.8 – 1.2 kg/t of galvanized material and depends on the oil content and the surface area of the articles.
Additions have to be made according to the ton of galvanized steel.
Monthly analysis will help to maintain the degreasing solution between 8-10% concentration.
Preparation of the Acidic Degreasing Solution
Calculate the volume of the tank
Fill 75% of the working level of the tank with water
Fill 8 to 10% of the working level with ANQA DEGREASER
Fill the rest of the tank to working level with water
LOW PHOSPHORIC ACIDIC DEGREASER FOR HOT DIP GALVANIZING INDUSTRY
ANQA DEGREASER removes oil and other impurities from the surface of steel.
Degreasing tanks should be acid resistant and be able to be heated to 35°C.
Technical Characteristics
Working Parameters pH : 1 – 2 Temperature : 30 – 40°C Process time : 10 – 30 minutes depending on the oil on steel substrate Iron concentration (Fe+2) : max 50 g/liter
Contains lower phosphoric acid
Lower amount of solids after degreasing Lower amount of solid waste
Contains surfactants
Increases degreasing efficiency
Contains corrosion inhibitors
Prevents acid attack to the steel