MONSTER INHIBITOR works by preventing the reaction between the acid and the base steel and allowing the reaction between the acid and the rust. It is absorbed on the surface of steel and form a layer that considerably reduces the attack of the acid on the metal. This reduces over pickling and lowers acid consumption.
Over pickling occurs when the pickling solution attacks and dissolves base metal after scale removal. The major causes are due to:
Different thicknesses of scale layers and some scale being more deeply embedded into the metal than others, all of which require more time for removal.
High temperature
High acid concentration
Long pickling time
Other quality problems due to over pickling also include possible hydrogen embrittlement (when the steel loses too much strength and becomes brittle) and excessive surface roughness due to pickling blisters.
Why Use MONSTER INHIBITOR in the Acid Solution?
Avoids excess dissolution of iron while cleaning the iron oxide
Provides better quality of galvanized product and reduce cost of pickling
Limits risk of hydrogen embrittlement in cold rolled and high strength steels
Extends the service life of the pickling solution by reducing the dissolution of the iron
Reduces the quantity of acid pickle waste.
Contains components that increase the wettability of the base steel in fluxing.
Smoothes the surface ensuring a better finish to the article and lowers pick-up of zinc.
The presence of MONSTER INHIBITOR has no negative effect on the pickling rate.
Fuming is reduced and there is less wear of the pickling facilities.
The MONSTER INHIBITOR concentration should be arranged by additions when fresh acid is added to pickling tanks.
Technical Characteristics
Preparation of the Pickling Solution with MONSTER INHIBITOR
Calculate the volume of the tank
Fill 50% of the working level of the tank with water
Fill MONSTER INHIBITOR in 1% of the amount of concentrated acid added in new bath
Fill the rest of the tank to working level with HCl
Maintenance of the Pickling Solution
Consumption of the chemical takes place by carry-over.
Additions have to be made according to the fresh HCl added, as 1% MONSTER INHIBITOR of the amount of concentrated acid added.
Working Parameters
Temperature : RT-35°C Process time : 15-90 minutes depending on the free HCl and Fe+2 content on the pickling solution Iron concentration (Fe+2) : Maximum 125 g/liter Free HCl concentration : Minimum 25 g/liter